After having bought the AC that’s just RIGHT for your room, the next important milestone is to get it installed under the guidance of a professional AC installation service provider. Quality of installation matters and certainly helps get more mileage from your AC unit. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
*(Lists tasks covered in addition to ones mentioned under Standard Installation Tasks) |
Here are glimpses of a day in the resQ engineer’s life showcasing superior Installation and its benefits:
1.Concealing the copper wiring: Superior Installation provides better routing and harnessing by concealing copper wires. In installation of a Split AC, a pair of copper pipes is used to connect the Indoor Unit (IDU) to the Outdoor Unit (ODU). In standard installation, these pipes are left bare affecting the décor of the room. However, if you opt for Superior Installation, the routing and harnessing is done in a manner that make the pipes seem to blend with the room décor: |
|
2. Using 2.5'' PVC pipes for wall hole: The PVC pipes provide a neat passage for copper pipes. The passage is then covered with white cement to prevent insects from entering the cavity area as also to provide for a refined look. The PVC pipes also protect the copper pipes from damage and pinching. |
3. Insulation of the flare nut points: Within standard installation, the insulation sleeves do not reach the flare nut points leaving an inch or two bare and exposed to heat. This can affect the efficiency of the air conditioner. Under superior installation the insulation sleeves reach the tip of the flare nuts and are tightened with wire so as to increase the cooling efficiency and the life of the insulation. |
4. Copper pipe clamping at every 2 feet: Clamping of the copper pipe reduces vibrations as a result of which the possibility of gas leakage significantly lowers. |
5. Inserting rubber pads between the Outdoor Unit (ODU) and the Wall/floor mount stand: The rubber pad reduces vibrations and noise produced by the compressor and minimizes chances of gas leak. It also decreases the risk of compressor failure. |
6. Providing for U-trap with the copper pipe: A U-trap is placed with the copper pipe, if the length of the pipe is more than 6 metres or if the Indoor Unit (IDU) is installed below the Outdoor Unit (ODU). The U-trap helps the compressor suck back the oil from the system much more efficiently. This keeps the compressor in good health. |
7. Fitting electric sockets: In case of unavailability of electrical socket resQ engineers will install an electrical socket near the machine or Fit an electrical box near the switch board. The power cables will be neatly harnessed using casing, capping. |
More on Superior Installation
Reliance resQ engineers undergo intensive training and grooming before they are dispatched to manage installations across all leading brands of AC. In addition to installation services resQ engineers also assist with heat load analysis & room size assessment to recommend the RIGHT AC that cools efficiently without producing astronomical bills.